Model EL-USB-CO
Single Channel Data Logger Measures and stores Carbon Monoxide (CO) readings over a 0 to 1000 ppm range
Stock
- Includes an EL-USB-CO data logger, a battery (pre-installed), and downloadable software
- PLEASE NOTE: The EL-USB-CO is a professional measuring instrument, designed to record Carbon Monoxide (CO) gas levels for later analysis. It is NOT an alarm/safety/warning device and should not be used in this capacity.
- 0 to 1000 ppm CO measurement range
- Stores up to 32,510 Measurements
- User-Programmable Warning Threshold with Bright Visual and Audible Warning
- USB Interface for Set-up and Data Download
- Expected sensor life: 4 years
- Replaceable Internal Lithium Battery
- Quantity Discount
Description
PLEASE NOTE: The EL-USB-CO is a professional measuring instrument, designed to record Carbon Monoxide (CO) gas levels for later analysis. It is not an alarm/safety/warning device and should not be used in this capacity.
The EL-USB-CO data logger measures and stores up to 32,510 Carbon Monoxide (CO) readings over a 0 to 1000 ppm measurement range and -10 to +40°C (14 to +104°F) operating temperature range. The user can easily set up the logging rate and start time, and download the stored data by plugging the data logger into a PC’s USB port and running the purpose-designed software. The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long life lithium battery. Data is stored in non-volatile memory and is retained when the battery is empty. A bright red LED will flash and a buzzer can sound when a preset warning level has been exceeded.
Accessories
Description
Replacement 3.6V, 1200mAh lithium battery. Please Note: Continental U.S. shipping ONLY.
Software
EasyLog Software
Configuration Software
FREE Configuration and download software for Lascar Data Loggers.
Specifications
Number of Channels: | One |
Measurement range: | 3 to 1000 ppm |
Internal resolution: | 0.5 ppm |
Accuracy (overall error): | the greater of ±7 / ±6 ppm/% |
Repeatability: | ±2 % of reading |
Decay of reading over time: | 5% of reading/year |
Expected sensor life: | 4 years |
Response time (to reach 90%): | 1 minute |
Logging Rate (current measurement): | 1 sample every 10 seconds 1 sample every 30 seconds 1 sample every minute 1 sample every 5 minutes |
Memory Capacity: | 32,510 samples |
Operating Temperature Range: (15-90%RH, non-condensing) |
-10 to +40°C (14 to +104°F) |
Operating pressure range: | 900 to 1000 mbar |
Battery Life: | 3 months (with battery supplied, 10 minute logging rate, 25°C ambient temperature, audible warning disabled, reading <10 ppm CO) |