DI-2008-DIRECT
Plug and Play DAQ for Mac, Macbook, Chromebook, Linux and SnapDragon Laptop and Windows. 8 channels Thermocouple and Voltage System, 16-bit Resolution, 7 D I/O
Why is high common mode important?
- Zero Installation & Universal Access WinDaq Direct Suite. Click portal above to enter
- Includes a DI-2008 configured for Mac, Macbook, Chromebook, SnapDragon laptops, Linux system and Windows, a 6-foot USB C to Mini cable, a screwdriver for signal connections, and an NIST-traceable calibration certificate
- Native support without the need of VM or Bootcamp from Mac or Macbook
- Eight differential and isolated analog input channels.
- Seven bi-directional digital input ports, controllable by WinDaq Direct's Automated Test Sequencer:
- Counter input for totalizing applications
- Rate input for frequency/flow/rpm applications
- Counter input is capable to capture frequency up to 2Mhz!
- Programmable voltage and thermocouple measurements per channel
- 10 mV to 50 V in 12 steps, 16-bit resolution measurements
- Type J, K, T, B, R, S, E, N thermocouples
- Use WinDaq Direct's Automated Test Sequencer for closed loop control and data logging
- 2000 Hz sample max throughput for a single channel and 200 Hz for two or more
- 15V (1W) supply output for 4-20mA sensors
- Use HMP60 Probe for Humidity Measurements
- 10% Education Discount
Description
DI-2008-DIRECT USB Thermocouple Data Acquisition system with Windaq Direct Suite. Specially configured for Mac, Chromebook, Linux, SnapDragon laptop and more. Features 8 analog input channels programmable as a thermocouple or voltage input, 16-bit measurement resolution, and a full scale range of ±10mV to ±50V for voltage measurements or Thermocouple types J, K, T, B, R, S, E, or N.
Eight analog input channels adapt to a wide range of measurement types and applications. Each channel can be independently programmed for a thermocouple or voltage measurement. Programmed as a voltage channel you can select one of twelve measurement ranges from ±10 mV to ±50 V. Programmed as a thermocouple channel you can select from eight thermocouple types: J, K, T, B, R, S, E, or N. Linearization and junction compensation are automatically applied by the DI-2008-DIRECT for the selected TC type to deliver values scaled in either °C or °F. Finally, all analog measurements benefit from a 16-bit ADC resolution to reveal even the smallest signal variations.
Enter the WinDaq™ Direct suite
Enter the WinDaq™ Direct suite—a revolutionary pair of high-performance web applications that bring the raw speed and hardware connectivity of classic desktop WinDaq directly to your internet browser, featuring a no-programming, point-and-click user interface.
WinDaq™ Direct Acquisition: Experience true plug-and-play data logging over Mac, Chromebook, SnapDragon and Linux system. This application connects directly to your DI-2008-DIRECT straight from your browser. Configure channels, apply real-time mathematical DSP, utilize digital storage oscilloscope trigger sweeps, and view live FFT or XY plots—all while streaming data flawlessly to a local file.
WinDaq™ Direct Waveform Browser: The ultimate successor to the classic WinDaq Waveform Browser (WWB). Instantly load, view, and analyze massive data acquisition files (.wdq, .wdh, .gbd, and .csv) entirely within your browser window. Just like the classic WWB, it automatically extracts channel metadata, applies y=mx+b scaling, and extracts trailing event markers (including precise timestamps and user comments), featuring a dropdown menu that allows you to jump instantly to critical moments in your data.
The Core Advantages:: 100% Secure and Local: "Browser-based" does not mean "cloud-uploaded." Whether you are logging live data or analyzing historical files, your data never leaves your computer. The applications interface strictly with your local hardware and hard drive, ensuring total data privacy, offline capability, and compliance with strict IT security protocols.
Hardware-Accelerated Rendering: While traditional web charts choke on large datasets, the WinDaq Direct Waveform Browser leverages an ultra-fast graphical engine. It renders millions of multi-channel data points smoothly, matching the high-speed panning and zooming engineers expect from native desktop software.
Zero-Footprint Agility: No software to download, install, or manage. Work seamlessly across Windows PCs, MacBooks, Chromebooks, and Linux environments. If you have a modern web browser, you have a professional-grade data acquisition system.
Accessories
Description
Teflon® coated or High Temp Glassbraisd J, K and T Thermocouples in various length. Learn More
Description
8mm diameter, 50-500mm length, 1/2" MNTP, stainless thermowells with cable gland to protect your thermocouples. Learn More
Description
250 Ω ±0.1% Precision, Metal Film, 1/2W, Axial Resistor
Exceptionally low noise; typically 0.10 μV/V
Low voltage coefficient to ±5 ppm/V
Flame retardant coating. RoHS
compliant.

Description
One AC/DC Current Clamp includes 9V battery and user manual. Download the DataSheet (pdf) to learn more or go to the product page. A banana jack to wire (pair), part number 2000429, is needed to connect this to the screw terminals

Description
Banana jack to wire (six inches long), perfect for connecting ACDC-256 to screw terminals

Description
AC Adapter for Sensor (such as 4-20mA) Excitation. Input: AC 100V-240V 50/60Hz; Output: 12V, 2A. Power Cable Length: 36.6 inch (0.9m).

Description
Measure Current from 0-1A up to 0-500A Input. 4-20mA Output. 4-20mA Current Loop Shunt Resistor Included. CE Compliance.

Description
2000362 Flow Sensor Measures 1-30L/min. Light weight, small size, durable, and easy to install. Inlaid with stainless steel impeller shaft. Lowest working voltage: DC4.5 5V-24V; Max current: 15 mA (DC 5V); Max operation temp: 120°C. Learn more.

Description
Allows you to power 5V rating sensor with a battery. Input voltage: DC8-35V, (12V/24V changes to 5V); Output parameter: DC5V 3A, 15W MAX

Description
4-20mA Output High precision pressure sensor measures PSI ranges of -14.5 to 14500 PSI, 8 or 12-30V supply voltagle dependant on models. Compatible with DI-2008, DI-4108M, DI-4208M and DI-808. Made with 316 stainless steel and high temperature auto-graded plastic. 0.25-0.5% accuracy. 4-20mA linear current output. 10% Educational Discount

Description
High precision pressure sensor measures PSI ranges of -14.5 to 14500 PSI dependant on models. Requires 101099 AD/DC adapter or 101087-1 DC/DC Converter to be used with DI-808, DI-2008, DI-4108M, DI-4208M, Graphtec Loggers. Made with 316 stainless steel and high temperature auto-graded plastic. 0.25-0.5% accuracy. 0.5V – 4.5V linear voltage output. 10% Educational Discount

Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for model DI-2008 Thermocouple and Voltage data acquisition product. Includes before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.

Description
Smartphone-Based Thermal Imager for Inspections and Troubleshooting. 19,200-pixel resolution and VividIR for enhanced image detail and clarity. Free Shipping. Learn more.



Description
6.6 ft USB-C to Mini USB Cable. Recommended for connection to laptops, Mac and Chromebook for use with WinDaq Direct.

Description
Ferrite choke reduces interference for USB-based data acquisition products.
Frequently Asked Questions
Can I record 4-20mA sensor signals and if so, how do I do that?
4-20-mA process current signals can be measured with the DI-2008. See How to make 4-20mA current Loop Measurements for more information.
Can I connect and measure data from a single-ended sensor?
Yes. Single-ended sensors can be connected and measured. The best practice is to connect the ground wire to the negative input of the channel.
Can I measure Thermocouple temperatures?
The DI-2008-DIRECT is specifically designed to measure and record thermcouple temperature measurements as well as voltage measurements.
Is the DI-2008-DIRECT Isolated?
Each DI-2008-DIRECT analog input is electrically isolated from other channels and from ground for safe and accurate measurements in the presence of common mode voltages. Channel isolation means that each analog input is free to float to an independent common mode voltage imposed upon it by the signal source up to 120 V rms, and still provide an accurate and noise-free measurement.
Does the DI-2008-DIRECT include a calibration certificate?
All new DI-2008-DIRECT instruments ship with an NIST-traceable calibration certificate.
Can I get the DI-2008-DIRECT re-calibrated?
Recalibration service is available and can be ordered online.
How often should I get the DI-2008-DIRECT re-calibrated?
The DI-2008-DIRECT should be re-calibrated annually.
Is my sensor compatible with this device?
Maybe. The many gain factors and voltage ranges available on the DI-2008-DIRECT allow for many sensors to be compatible with the device. See how fine a measurement you can make with your sensor using the ADC Resolution Calculator. If you have any questions about compatibility just send your sensor information to our sales team at sales@dataq.com.
Does the DI-2008-DIRECT include digital or analog output channels?
The DI-2008-DIRECT has seven bi-directional digital ports, and they can be controlled by WinDaq Direct Automated Test Sequencer
My sensor requires a power source, can the DI-2008-DIRECT provide that power?
Yes. The DI-2008-DIRECT can provide +15V power by connecting the appropriate wire to the +15V pin. Be sure your sensor does not exceed the excitation output spec: +15 V dc (-7.5% to +2.5%) at 70% load (47 mA), 67 mA at full load.
Specifications
| Analog Inputs | ||||||||||||||||||||||||||||
| Number of Channels: | 8 | |||||||||||||||||||||||||||
| Configuration: | Differential, Isolated | |||||||||||||||||||||||||||
| Programmable measurements per channel: | Voltage, Thermocouple | |||||||||||||||||||||||||||
| Programmable thermocouple types and measurement range per channel: Over 25 ±5 °C ambient temperature range. Stable ambient temperature. Following 30 minutes warm-up. Excluding common mode error. Excluding thermocouple error. |
|
|||||||||||||||||||||||||||
| Programmable voltage measurement ranges per channel: | ±10 mV, ±25 mV, ±50 mV, ±100 mV, ±250 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V, ±10 V, ±25 V, ±50 V | |||||||||||||||||||||||||||
| Voltage measurement accuracy: At 25 °C ambient temperature. Following 30 minutes warm-up. Excluding common mode error. |
±(0.05% of range + 10 µV) | |||||||||||||||||||||||||||
| Input impedance: | 1 MΩ, all ranges | |||||||||||||||||||||||||||
| Isolation: | 350Vpp, Input-to-output, Channel-to-channel | |||||||||||||||||||||||||||
| Absolute maximum input without damage: | 120 V rms | |||||||||||||||||||||||||||
| Maximum common mode voltage: | 120 V rms | |||||||||||||||||||||||||||
| Min common mode rejection (330Ω unbalance): | >100 dB (DC to 60 Hz) | |||||||||||||||||||||||||||
| Channel-to-channel crosstalk rejection: (Rsource ≤ 330 Ω; Freqsource ≤ 60 Hz) | > 100 dB at any throughput | |||||||||||||||||||||||||||
| Digital Inputs | ||||||||||||||||||||||||||||
| Number of ports: | 7 | |||||||||||||||||||||||||||
| Type: | MOSFET switch | |||||||||||||||||||||||||||
| Configuration: | Programmable as an input or switch | |||||||||||||||||||||||||||
| Pull-up value: | 4.7 KΩ | |||||||||||||||||||||||||||
| Isolation: | None | |||||||||||||||||||||||||||
| Input high voltage threshold: | 2.4 V minimum | |||||||||||||||||||||||||||
| Input low voltage threshold: | 0.8 V maximum | |||||||||||||||||||||||||||
| Absolute max input without damage: | 0 ≤ V ≤ 30 V | |||||||||||||||||||||||||||
| Count/Rate | ||||||||||||||||||||||||||||
| Digital port assignment: | Count: Port 2 configured as input Rate: Port 3 configured as input |
|||||||||||||||||||||||||||
| Internal pull-up value: | 4.7 kΩ | |||||||||||||||||||||||||||
| Input high voltage threshold: | 2.4 V | |||||||||||||||||||||||||||
| Input low voltage threshold: | 0.8 V | |||||||||||||||||||||||||||
| Terminal count: | 65,535 | |||||||||||||||||||||||||||
| Maximum rate frequency: | 50 kHz | |||||||||||||||||||||||||||
| Minimum rate frequency: | 0.5 Hz | |||||||||||||||||||||||||||
| Maximum count frequency: | 50 kHz | |||||||||||||||||||||||||||
| Power | ||||||||||||||||||||||||||||
| Power Consumption: | 0.75 Watts (from USB port) | |||||||||||||||||||||||||||
| Excitation output: | +15 V dc (-7.5% to +2.5%) at 70% load (47 mA), 67 mA at full load, or max three 4-20mA sensors | |||||||||||||||||||||||||||
| ADC Characteristics | ||||||||||||||||||||||||||||
| Voltage Measurement Resolution: |
|
|||||||||||||||||||||||||||
| Thermocouple Temperature Measurement Resolution: |
|
|||||||||||||||||||||||||||
| 4-20 mA current loop resolution: | 13,100 ADC counts over the 4-20 mA range (5 VFS range with 250-Ω shunt resistor) | |||||||||||||||||||||||||||
| Maximum sample throughput rate: | Single enabled channel: 2,000 S/s Two or more enabled channels: 200 S/s |
|||||||||||||||||||||||||||
| Minimum sample throughput (hardware): | 1 enabled analog channel: 0.000109 S/s 2 or more enabled analog channels: 0.000011 S/s |
|||||||||||||||||||||||||||
| Minimum sample throughput (using WinDaq): | .0001969 S/s | |||||||||||||||||||||||||||
| Sample rate timing accuracy: | 50 ppm | |||||||||||||||||||||||||||
| Indicators and Connections | ||||||||||||||||||||||||||||
| Interface: | USB 2.0 (mini-B style connector) | |||||||||||||||||||||||||||
| Indicator lights: | 3 LEDs: Power, Active, Event | |||||||||||||||||||||||||||
| Input Connections: | Two 16-position terminal strips | |||||||||||||||||||||||||||
| Environmental | ||||||||||||||||||||||||||||
| Operating Temperature: | 0 to 70 °C | |||||||||||||||||||||||||||
| Storage Temperature: | -20 to 70 °C | |||||||||||||||||||||||||||
| Storage Humidity: | 0 to 90% non-condensing | |||||||||||||||||||||||||||
| Physical Characteristics | ||||||||||||||||||||||||||||
| Enclosure: | Hardened Plastic | |||||||||||||||||||||||||||
| Mounting: | Desktop; bulkhead | |||||||||||||||||||||||||||
| Dimensions: | 3.28D × 6.68W × 1.13H in. (83.31D × 169.67W × 28.7H mm.) | |||||||||||||||||||||||||||
| 3D Model | Click here | |||||||||||||||||||||||||||
| Weight: | 5.7 oz. (162 grams) | |||||||||||||||||||||||||||
| Software Support | ||||||||||||||||||||||||||||
| WinDaq Direct software: | OS support | |||||||||||||||||||||||||||
Articles
How to Acquire Flow Rate and Flow Volume using a DATAQ Data Logger
Making Parallel Thermocouple Measurements
How To Make 4-20 mA Current Loop Measurements
Videos
Pressure Measurements
Learn how to make pressure Measurements with a pressure sensor and Dataq products.


View Cart
sales@dataq.com
330-668-1444
Share