Model DI-5B33-03
Isolated 10V RMS 5B-style Amplifier
Stock
- Interfaces RMS Voltage (10V)
- Designed For Standard Operation With Frequencies of 45Hz to 1kHz (Extended Range to 20kHz)
- Compatible With Standard Current and Potential Transformers
- ±0.25% Factory Calibrated Accuracy (Accuracy Class 0.2)
- 1500 VRMS Continuous Transformer Based Isolation
- Input Overload Protected to 480V Max (Peak AC and DC) or 10A RMS Continuous
- ANSI/IEEE C37.90.1-1989 Transient Protection
- View Dimensions and pinout
Description
Each DI-5B33 True RMS input module provides a single channel of AC input which is converted to its True RMS dc value, filtered, isolated, amplified, and converted to a standard voltage output (see block diagram).
The DI-5B modules are designed with a completely isolated computer side circuit which can be floated to ±50V from Power Common, pin 16. This complete isolation means that no connection is required between I/O Common and Power Common for proper operation of the output switch. If desired, the output switch can be turned on continuously by simply connecting pin 22, the Read-Enable pin to I/O Common, pin 19.
The field voltage input signal is processed through a preamplifier and RMS converter on the field side of the isolation barrier. The converted dc signal is then chopped by a proprietary chopper circuit and transferred across the transformer isolation barrier, suppressing transmission of common mode spikes and surges. The computer side circuitry reconstructs, filters and converts the signal to industry standard outputs. Modules are powered from +5VDC, ±5%.
Accessories
Description
16-channel backplane for 5B modules. Each module has its own analog bus. For use with DI-5B Modules.
Description
Single-channel backplane. For use with DI-5B Modules.
Description
Dual-channel backplane. For use with DI-5B Modules.
Description
8-position analog I/O backplane, non-multiplexed. For use with DI-5B Modules.
Description
Base element with snap foot required for use with models DI-5B03 and DI-5B04 Backplanes. For use with DI-5B Modules.
Description
5V DC Power Supply for use with both DI-5B and DI-8B Backplanes.
Description
Side element required for use with models DI-5B03 and DI-5B04 Backplanes. For use with DI-5B Modules and Backplanes.
Specifications
Input | |
Signal Range: | 0V to 10V RMS |
Standard Frequency Range: | 45Hz to 1000Hz |
Extended Frequency Range: | 1kHz to 20kHz |
Impedance: | 1MΩ ±1% shunted by 100pF |
Coupling: | AC |
Protection: (Module Rating Only) |
Continuous: 480V (Peak AC & DC) Transient: ANSI/IEEE C37.90.1-1989 |
Accuracy* | |
Sinusoid: | 50/60Hz: ±0.25% Span 45Hz to 1kHz: ±0.25% Reading Additional Factor 1kHz to 20kHz: ±0.75% Reading Additional Factor |
Non-Sinusoid: | Crest Factor = 1 to 2: ±0.05% Reading Additional Error Crest Factor = 2 to 3: ±0.15% Reading Additional Error Crest Factor = 3 to 4: ±0.30% Reading Additional Error Crest Factor = 4 to 5: ±0.40% Reading Additional Error |
Vs. Temperature: | ±100ppm/°C |
Isolation | |
Input to Output, Input to Power: | Continuous: 1500Vrms max Transient: ANSI/IEEE C37.90.1-1989 |
Output to Power (Continuous): | 50Vdc max |
Output Enable Control | |
Selection Time: | 6.0µS @ Cload = 0 to 2000pF |
Voltage: | Max Logic “0”: +0.8V Min / Max Logic “1”: +2.4V / +36V |
Current, “0,1”: | 0.5µA |
Other | |
Rejection (50-60Hz Common Mode): | 100dB |
Response Time (0 to 99%): | <400ms |
Loop Voltage: | +14Vdc min, +48Vdc max |
Load Resistance (maximum): | (Loop Voltage -14) / (Loop Current) |
Supply Voltage: | +5VDC ±5% |
Supply Current: | 30mA |
Supply Sensitivity: | ±200µV/% RTI |
Environmental: | Operating Temperature: -40ºC to +85ºC Storage Temperature: -40ºC to +85ºC Relative Humidity: 0 to 90% Noncondensing |
Mechanical Dimensions: | 2.28" × 2.26" × 0.60" (58mm × 57mm × 15mm) |
* At standard 60Hz factory calibration. For 10 to 100% rated span. Add an additional 0.25% error for 0 to 10% Span measurements. Accuracy includes nonlinearity, hysteresis and repeatability but not source or external shunt inaccuracy (if used).
Articles
Bandwidth Considerations for DI-5B and DI-8B Signal Conditioning Modules
Learn the Importance of Isolation In Four Easy Lessons
How To Calibrate Strain Gage-Based Transducers Using DI-5B38 Strain Amplifiers