WinDaq Control > Methods > DAOutput |
DAOutput
Applies to: |
WINDAQ Active X Control |
Description: |
Sends a single signal to the digital-to-analog (DAC) port if available. The DAC ports (if available) are labelled on your hardware device as DAC1 (Port 0) or DAC2 (Port 1). There are two parameters for this function: The first parameter is the signal you would like to send to the DAC port. This value can be +/-10. The second parameter is the port you are sending the signal to. This can be either 0 or 1. 0 sends the signal to DAC1 (Port 0) and 1 sends the signal to DAC2 (Port 1). |
Syntax: |
WinDaq1.DAOutput(Data,Port) (where Data is between 10V and -10V and Port is either 0 for Port 0 (DAC1) or 1 for Port 1 (DAC2)) |
Variables: |
|
Example: |
Dim sw As Boolean
Private Sub Command2_Click() Timer1.Enabled = False Timer2.Enabled = False End Sub
Private Sub Command1_Click() WinDaq.Start Timer1.Enabled = True Timer2.Enabled = True End Sub
Private Sub Timer1_Timer() 'sends out a square wave according to Timer interrupt 'you can reach around 20Hz update rate here If sw = True Then WinDaq.DAOutput Text1.Text, 0 Else WinDaq.DAOutput Text2.Text, 1 WinDaq.DAOutput Text2.Text, 0 End If sw = Not sw End Sub
Private Sub Timer2_Timer() DQChart1. Chart (WinDaq. GetDataFrame(DQChart1. Xmax, FormatBinary)) End Sub |