WinDaq Control > Methods > GetMinLimit

Previous | Next

GetMinLimit

Applies to:

WINDAQ Active X Control

Description:

Returns the negative full scale limit for the specified channel in calibrated units (use GetUnit to return the engineering units).

The channel is the logical channel in the index on the channel list, not the physical channel. For example, if the channel list is 1, 5, 8, 9, 10, and you want the negative full scale limit of channel 8, you would set the channel argument of GetMinLimit to 2. If you want the negative full scale limit of channel 1, you would set the channel argument of GetMinLimit to 0.

Syntax:

variable=WinDaq.GetMinLimit(Channel) (where Channel is the logical channel in the index on the channel list)

Variable:

Double

Example:

Private Sub Stop_Click()

WinDaq1. Stop

End Sub

 

Private Sub Start_Click()

WinDaq1. EventLevel = 10

WinDaq1. Start

End Sub

 

Private Sub WinDaq1_ NewData(ByVal Count As Integer)

DQChart1. Chart (WinDaq1. GetDataStream(FormatBinary))

'this gets information associated with the first channel

Label1.Caption = "The negative full scale limit is " & WinDaq1.GetMinLimit(0)

End Sub

 