Model HMP60
Humidity Sensor Measures -40 to +60 °C, 0 to 100% RH Measurement Range
Stock
- -40 to +60 °C, 0 to 100% RH Measurement Range
- Rugged IP-65 rated metal construction (protected from dust and low pressure water jets)
- Low power consumption
- 2.5 V output
- Sensor easily replaced
- Compatible data acquisition instructments
![HMP60 Temperature and Humidity Sensor](/resources/images/HMP60-temperature-humidity-sensor.jpg)
Description
The HMP60 measures -40 to +60 °C and 0 to 100% RH when connected to a Dataq Instruments Data Acquisition product or Data Logger.
The HMP60 sensor allows Dataq data loggers to acquire relative humidity (RH) and temperature information. The combination of these two products provides a compact solution, with transducer excitation provided by the data logger. The logger itself allows data to be communicated to a connected PC over either a USB or Ethernet interface. Optionally, many Dataq Instruments hardware can store data to a removable SD-style memory card to satisfy stand-alone applications. Even with a connected HMP60, Dataq Instruments' Systems multi-channel capacity allows additional channels of information to be acquired and correlated with temperature and humidity information to satisfy nearly any level of measurement expansion.
Accessories
![HMP60 sensor](/resources/images/products-150/snsr-hmp60.jpg)
Description
Spare humidity sensor for HMP60 Temperature and Humidity Probe.
![HMP60 nuts](/resources/images/products-150/nut-hmp60.jpg)
Description
Spare plastic mounting nuts, hex M12x1, plastic (pair).
![AC/DC Adapter for Sensor Excitation](/resources/images/products-150/ac-dc-adapter-excitation-power-101086.jpg)
Description
AC Adapter for Sensor (such as 4-20mA) Excitation. Input: AC 100V-240V 50/60Hz; Output: 12V, 2A. Power Cable Length: 36.6 inch (0.9m).
Specifications
Temperature | |
Measurement Range: | -40°C to +60°C |
Accuracy over temperature range (-40 to +60 °C): | ±0.6°C |
Relative Humidity | |
Measurement Range: | 0 to 100% RH |
Typical Accuracy (0 to +40°C): | 0 to 90% RH: ±3% RH 90 to 100% RH: ±5% RH |
Typical Accuracy (-40 to 0°C and +40 to +60°C): | 0 to 90% RH: ±5% RH 90 to 100% RH: ±7% RH |
Dew Point | |
Measurement Range: | -40°C to +60°C |
Typical Accuracy (0 to +40°C): | ±2 °C (when dew point depression < 15 °C) |
Typical Accuracy (-40 to 0°C and +40 to +60°C): | ±3 °C (when dew point depression < 10 °C) |
Inputs and Outputs | |
Operating Voltage: | 5 to 28 VDC |
Power Requirements: | 56mW |
Settling time at power up: | 150ms |
Start-up time at operating voltage: | <14 V: 1 s; >14 V: 4 s |
Outputs: | 0 to 2.5 VDC (equals 0% to 100% RH and -40°C to +60°C) |
External loads: | RL min 50kΩ |
Environment | |
Operating Relative Humidity: | 0% to 100% RH |
Operating/Storage Temperature: | -40°C to +60°C |
Electromagnetic compatibility: | Complies with EMC standard EN61326-1, Basic immunity test requirements |
Mechanical | |
Materials body: | Chrome coated aluminum |
Materials grid/filter: | Chrome coated ABS plastic |
Materials cable: | Polyurethane or FEP |
Body thread: | MI2x1 / 10 mm |
Grid thread: | M11x1 / 5mm |
Cable connector: | 4-pin M8 female |
Weight: | 3.5 oz (99 grams) includes cable |
Logger inaccuracy not included in these specifications.