Model HMP60
Humidity Sensor Measures -40 to +60 °C, 0 to 100% RH Measurement Range
Stock
- -40 to +60 °C, 0 to 100% RH Measurement Range
- Rugged IP-65 rated metal construction (protected from dust and low pressure water jets)
- Low power consumption
- 2.5 V output
- Sensor easily replaced
- Compatible data acquisition instructments
Description
The HMP60 measures -40 to +60 °C and 0 to 100% RH when connected to a Dataq Instruments Data Acquisition product or Data Logger.
The HMP60 sensor allows Dataq data loggers to acquire relative humidity (RH) and temperature information. The combination of these two products provides a compact solution, with transducer excitation provided by the data logger. The logger itself allows data to be communicated to a connected PC over either a USB or Ethernet interface. Optionally, many Dataq Instruments hardware can store data to a removable SD-style memory card to satisfy stand-alone applications. Even with a connected HMP60, Dataq Instruments' Systems multi-channel capacity allows additional channels of information to be acquired and correlated with temperature and humidity information to satisfy nearly any level of measurement expansion.
Accessories
Description
Spare humidity sensor for HMP60 Temperature and Humidity Probe.
Description
Spare plastic mounting nuts, hex M12x1, plastic (pair).
Description
AC Adapter for Sensor (such as 4-20mA) Excitation. Input: AC 100V-240V 50/60Hz; Output: 12V, 2A. Power Cable Length: 36.6 inch (0.9m).
Specifications
Temperature | |
Measurement Range: | -40°C to +60°C |
Accuracy over temperature range (-40 to +60 °C): | ±0.6°C |
Relative Humidity | |
Measurement Range: | 0 to 100% RH |
Typical Accuracy (0 to +40°C): | 0 to 90% RH: ±3% RH 90 to 100% RH: ±5% RH |
Typical Accuracy (-40 to 0°C and +40 to +60°C): | 0 to 90% RH: ±5% RH 90 to 100% RH: ±7% RH |
Dew Point | |
Measurement Range: | -40°C to +60°C |
Typical Accuracy (0 to +40°C): | ±2 °C (when dew point depression < 15 °C) |
Typical Accuracy (-40 to 0°C and +40 to +60°C): | ±3 °C (when dew point depression < 10 °C) |
Inputs and Outputs | |
Operating Voltage: | 5 to 28 VDC |
Power Requirements: | 56mW |
Settling time at power up: | 150ms |
Start-up time at operating voltage: | <14 V: 1 s; >14 V: 4 s |
Outputs: | 0 to 2.5 VDC (equals 0% to 100% RH and -40°C to +60°C) |
External loads: | RL min 50kΩ |
Environment | |
Operating Relative Humidity: | 0% to 100% RH |
Operating/Storage Temperature: | -40°C to +60°C |
Electromagnetic compatibility: | Complies with EMC standard EN61326-1, Basic immunity test requirements |
Mechanical | |
Materials body: | Chrome coated aluminum |
Materials grid/filter: | Chrome coated ABS plastic |
Materials cable: | Polyurethane or FEP |
Body thread: | MI2x1 / 10 mm |
Grid thread: | M11x1 / 5mm |
Cable connector: | 4-pin M8 female |
Weight: | 3.5 oz (99 grams) includes cable |
Logger inaccuracy not included in these specifications.