Model DI-160
Event, State, and Count Data Logger Records When, How Long, and How Many Times Events Occur
Stock
Replaced by DI-2160
- Includes a DI-160 instrument, a 6-foot USB cable, an AC power adapter, a 2GB SD memory card, a rechargeable lithium-ion battery (pre-installed) as power backup (1-2 hour life), and downloadable recording software
- Logs when, how long, and how many times events occur
- Eight measurement channels
- Four isolated high voltage inputs connect to any ±300V or 230 VAC rms source
- Four low voltage inputs to detect activity from switch closures, TTL-level signals, or DC levels (up to 30 Volts)
- Records to removable, SD-style memory in csv (comma-separated value) file format
- Pre-installed rechargeable lithium-ion backup battery for sudden power loss (lasts about 24 hours)
- Four measurement modes
- Built-in USB interface
- CE approved
Description
The DI-160 USB Event Data Logger features 8 input channels (four high and four low) with programmable capture modes to detect events (when the events happen), states (how long between events) and counts (how many events).
The DI-160 features programmable capture modes to detect events (when the events happen), states (how long between events) and counts (how many events). An internal real time clock provides time and date stamping for each captured quantity, and storage is accomplished to a removable SD-style memory card. Data storage format is comma-separated value (CSV) so recorded files are human-readable and easily imported to other applications like Microsoft Excel.
The DI-160 features eight input channels split between four high voltage and four low voltage types. The high voltage channels may be connected to any ±300V or 230 VAC rms source and feature input-tooutput and channel-to-channel isolation of 500 VDC or ±250 V peak AC. The four low voltage inputs are internally pulled-up and may be used to detect activity from switch closures, TTL-level signals, or DC levels up to 30 Volts.
The unit can be powered by an AC adaptor or an internal rechargeable battery. Three status LEDs are provided: USB interface detected, sampling, and battery charging.
Accessories
Description
2GB SD memory card allows recording up to a 2 kHz sample throughput rate. See model 101014-2G for a faster memory solution.
Description
USB Secure Digital Memory Card Reader connects to the USB port of any PC and allows data recorded to SD memory to be transferred to the PC for review and analysis.
Description
Optional AC power supply (USB to AC) for stand-alone applications and charging EL-WiFi Series products. Includes US adapter.
Description
Spare US Adapter for AC power supply 101017-2 and 101085.
Description
Spare European Adapter for AC power supply 101017-2 and 101085.
Description
Spare UK Adapter for AC power supply 101017-2 and 101085.
Description
Spare Australian Adapter for AC power supply 101017-2 and 101085.
Software
Event Recorder Software
DI-160 Configuration
FREE Setup and configuration software for DI-160 Event, State, and Count Data Loggers.
Specifications
High Voltage Signal Inputs | |
Number of Channels: | 4 |
Working Range: | ±300 VDC, 230 Vrms |
Trigger Threshold: | 4 Volts |
Channel-to-channel Isolation: | 500 V DC, ±250 V peak AC |
Input-to-output Isolation: | 500 V DC, ±250 V peak AC |
Max Input without Damage: | ±360 V DC or peak AC |
Low Voltage and Switch Closure Inputs | |
Number of Channels: | 4 |
Configuration: | Internally pulled up |
Working Range: | TTL |
Trigger Threshold: | 2.5 V DC |
Isolation: | None |
Max Input without Damage: | ±30 V DC or peak AC |
Operation | |
Programmable functions: | Event, State, Count (alternating current (AC) counter or high-speed (HS) counter; HV channels 1-3 and LV channels 5-7 may function as counters, but no more than three counters can be enabled at any time.) |
Programmable intervals: (applies to all channels) |
1, 2, 5, 10, 15, 30 seconds 1, 2, 3, 4, 5, 10, 15, 30 minutes 1, 2, 4, 6, 8, 12, 24 hours |
Counter Operation | |
Reset condition: | Programmable interval timeout |
Maximum count: | 1 sec interval, 8,192 >1 sec interval, 9,999 |
Maximum frequency: | 2 kHz |
Minimum pulse width: | > 500 μs |
HS Counter Operation: | Used whenever the need exists to account for and totalize each pulse that occurs within a sample interval |
AC Counter Operation: | Optimized for 50/60 Hz power line frequencies. Designed to ignore power line transitions and to change state only when power is removed or applied. Maximum line frequency: 120 Hz Maximum count frequency: 20 Hz |
State Operation | |
Operation: | Determines the DURATION of an event. Records the state that exists upon termination of a sample interval. |
Event Operation | |
Operation: | Determines WHEN an event occurred, but does not yield the duration of the event. Records a single time-stamped data point when one or more events occur within a definable interval. |
Min capture event pulse width: | > 500 µs |
Internal Date/Time Clock | |
Accuracy: | 20 ppm |
Sync Method: | via connected PC during setup |
System Configuration | |
Method: | Via PC-based program; Uploaded via USB port |
Parameters: | Enabled/disabled channels; Sample interval; Function (AC counter, HS counter, Event, Pulse); User annotation per channel; Device name |
Data Memory | |
Type: | Removable SD-style |
Maximum memory size: | 2 GB |
Storage format: | ASCII comma separated value (.csv) |
Controls, Indicators, and Connections | |
Interface: | USB 2.0 (mini-B style connector) |
Storage: | Removable SD-style memory |
Push button control: | Stop/Start recording to SD memory |
Indicators (LED): | Active, USB, Battery |
Input Connections: | One 16-position terminal strip divided into two sections (High Holtage and Switch Closure/TTL) |
Power | |
Internal Battery Type: | Rechargeable lithium-ion |
Internal Battery Run time: | 24 hours |
Current drain: | 450 mA max @ 5VDC |
AC adapter: | 100-240 VAC, 50-60 Hz |
External Power: | via USB port or provided AC adapter |
Environmental | |
Operating Temperature: | 0°C to 35°C (32°F to 95°F) |
Operating Humidity: | 0 to 90% non-condensing |
Storage Temperature: | -20°C to 45°C (-4°F to 113°F) |
Storage Humidity: | 0 to 90% non-condensing |
Physical Characteristics | |
Enclosure: | Hardened Plastic |
Mounting: | Desktop; bulkhead |
Dimensions: | 2.625D × 5.5W × 1.53H in. (6.67D × 13.97W × 3.89H cm.) |
Weight: | 4.5 oz. |
OS Compatibility | |
Setup software: | Windows XP (32-bit) and later |
SD-based CSV files: | OS-independent |
Similar Products
Quick Product Comparison
Model | Input Channels | Expandable* | Measurements | Data Storage | Interface | Counter Channel |
Rate Channel |
Price |
DI-160 | 8 (four high and four low) | - | Event, State, Count | PC or SD memory | USB | Yes | Yes | $299 |
DI-161 | 8 isolated | - | Event, State, Count | PC or Cloud | Ethernet | Yes | Yes | $629 |
EL-USB-5 | 1 | - | Event, State, Count | Internal | USB | Yes | Yes | $91.99 |
DI-1100 | 4 | - | ±10 Volts | PC | USB | - | - | $59 |
*Expand with ChannelStretch™. Compatibility with other units dependent on model.