Stock
The DI-718B-ES Bundle includes the following products:
- DI-718B-ES Ethernet Data Logger and Data Acquisition System ($895 value)
- WinDaq/XL software — A Real time link to Microsoft Excel (2003 version or better) requiring no programming ($99 value)
- An Unlock Code for high speed data acquisition with WinDaq software ($595 value)
- A High Speed 2GB SD Card ($45 value)
- A USB SD Card Reader ($25 value)
The DI-718B-ES has the following features:
- Measures temperature, pressure, flow, current, voltage, and more using isolated 8B amplifiers. At least one 8B module is required. View the DI-8B amplifier selection guide
- Low-Cost, Portable, Ethernet Data Acquisition System. This product is similar to the DI-710 Series but with Signal Conditioned inputs.
- Stand-alone data logger option allows in-the-field measurements to be saved to Secure Digital Cards (SD).
- Eight DI-8B signal-conditioned analog inputs. For a 16 channel version see the DI-718Bx Series.
- 14-bit analog to digital conversion.
- Includes WinDaq Software.
- Record up to 14,400 Hz in stand-alone mode using high speed SD card (model 101014-2G)
- Up to 4800 Hz Sample Throughput Rate when connected to PC
- Unlock code required for sample rates over 1,108 Hz only when using WinDaq software
- Wide variety of measurement functions and ranges based on DI-8B module selections. Mix and match modules as needed.
- Find out how long your data logger can record to SD memory using our Record Time Calculator
This model is soon to be discontinued. Please consider the DI-4718B-E as a direct replacement. See comparison
Description
Low-cost, portable, Ethernet data acquisition system with stand-alone capability (records to SD card) featuring 8 inputs for DI-8B signal conditioning modules (not included), a maximum throughput rate up to 14400 samples/second to flash memory. Includes power cable, Ethernet cable, bare stereo jack for remote control operations, software, and documentation.
DATAQ Instruments’ DI-718B Series is a four-product family of instruments designed for general purpose and standalone data logging applications that require signal conditioning. Interface options are USB or Ethernet. DI-718B instruments may also be purchased with or without stand-alone capability. Instruments without this option must remain tethered to a PC’s USB or Ethernet port during data acquisition and use the PC’s own program and memory to store acquired data. Instruments with the stand-alone data logging option feature a built-in socket that accepts standard Secure Digital (SD) memories to which acquired data may be stored. SD memories are the same commonly available mass storage devices used with digital cameras and MP3 players.
Compact and low cost DI-8B amplifiers may be plugged directly into the DI718B and are the world’s smallest fully functional isolated analog signal conditioners. Each DI-8B module protects, filters, amplifies, and isolates an input signal and provides an advanced signal conditioning solution for nearly any industrial measurement. The compact nature of both the DI-718B and DI-8B modules combine to form the smallest data logger/acquisition instrument in its class. All DI-718B instruments are supplied with dual, removable, 16-position screw terminal connectors to provide access to the built-in DI-8B module backplane. Instruments are housed in a small (13.81D × 10.48W × 3.81 centimeters; 5.4375D × 4.125W × 1.5H inches) enclosure consisting of an aluminum base, all-steel wraparound, and aluminum end plates.
Accessories
Description
DI-8B amplifiers offer the convenience to mix and match modules based upon measurement function and range to meet any application requirement, from the most simple to the most complex.
101014-2G
2GB SD Card (High Speed)
Description
High-speed 2GB SD memory card allows recording to the full stand-alone sample rate limit of the host data logger.
Description
2GB SD memory card allows recording up to a 2 kHz sample throughput rate. See model 101014-2G for a faster memory solution.
Description
USB Secure Digital Memory Card Reader connects to the USB port of any PC and allows data recorded to SD memory to be transferred to the PC for review and analysis.
Description
Unlocks WinDaq to allow recording speeds up to 4.8 kHz throughput. Unlock Code ONLY. No CD will be shipped. Please Note: If you are ordering this software for a device you already own, you MUST provide the serial number of your device under "Order Notes" during checkout to receive the unlock code. Please allow one (1) business day for processing.
Description
Replacement 16-port removable screw terminal block for BOTTOM of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Replacement 16-port removable screw terminal block for TOP of screw terminal block receptacle in DI-78B, DI-710, DI-718B, DI-4718B, DI-718Bx, DI-785, DI-788, and DI-808 products.
Description
Spare power supply for DI-710, DI-718B, and DI-1000TC products.
Description
Spare Australian Adapter for AC power supply 101017-2 and 101085.
Description
Spare UK Adapter for AC power supply 101017-2 and 101085.
Description
Spare European Adapter for AC power supply 101017-2 and 101085.
Description
Spare US Adapter for AC power supply 101017-2 and 101085.
Description
Power Connector for DI-1000TC, DI-710, and DI-718B products.
Description
Re-calibration Service, this calibration certificate is included with new instruments. NIST-traceable certificate for all DI-710, DI-718B, and DI-718Bx data acquisition and data logger products. Includes both before and after data. Shipping charges do apply when ordering online. Learn more about Calibrating your device.
Description
Pair of angle mounting brackets (with mounting screws) for DI-4718 Series, DI-4108 Series, DI-4208 Series, DI-808 Series, DI-710 Series, DI-718B Series, and DI-100TC Series instruments
Software
WinDaq
Data Acquisition Recording and Playback Software
Included FREE with your DI-710 purchase. Installs drivers and WinDaq recording and playback software. Includes optional Add-on software with a valid installation key. 1108Hz maximum sample rate. For higher rates purchase the unlock code under the Accessories tab.
ActiveX Controls
Programming
FREE ActiveX programming solutions for Dataq Instruments products. Free sample programs available. Compatible with LabView.
WinDaq/XL
WinDaq-to-Excel Real Time Link
Real-time data logging directly to Microsoft Excel (supports MS Office 2003 or higher). No programming required. Free Trial Version. Purchase full version on WinDaq/XL product page.
Advanced CODAS
$595
Advanced analysis software add-on to WinDaq Waveform Browser software. Allows calculated channels, derivative, integration, moving average, automatic file management, automatic scaling, and more.
Specifications
Analog Inputs | |
Number of Channels: | 8 configured for signal conditioned inputs |
Channel Configuration: | Defined by DI-8B Module |
Measurement Range: | Defined by DI-8B Module |
Accuracy: | ±0.25% FSR (at 1800 S/s, averaging mode) |
Resolution: | ±1 part in 8,192 |
Input Impedance: | Defined by DI-8B Module |
Input offset voltage: | Defined by DI-8B Module |
Channel-to-channel crosstalk rejection: | -75db @ 100Ω unbalance |
Offset temperature coefficient: | 0.25µV/°C |
Digital filtering: | Standard: Conditional over-sampling Stand-alone: None |
CJC Error: | 1.5°C plus 8B Module |
Isolation (via DI-8B Modules) | |
Input-to-Output: | 1000VDC/Peak AC |
Channel-to-Channel: | 500VDC/Peak AC |
A/D Characteristics | |
Type: | Successive approximation |
Resolution: | 14-bit |
Monotonicity: | ±2 LSB |
Conversion Time: | 69.4µs |
Scanning Characteristics | |
Max. throughput sample rate: | Standard: 4,800 Hz Stand-alone: 14,400 Hz* |
Min. throughput sample rate: | Standard: 0.0034 Hz Stand-alone: 0.0017 Hz |
Max. scan list size: | 9 entries |
Sample buffer size: | 2kb |
Calibration | |
Calibration cycle: | One year |
Calibration method: | Calibration Software, provided |
Controls (Stand-alone models) | |
Single push-button: | Provides manual control over Record and Standby |
Digital I/O | |
Bits: | 2 Inputs (Remote Storage and Remote Events) |
Input voltage levels: | Min. required “1” 2V; Max allowed “0” 0.8V |
Ethernet Interface | |
Type: | 10/100Base-T |
Connector: | RJ-45 |
Protocol: | TCP/IP |
Server Type: | DHCP or Fixed IP |
Removable Memory (Stand-alone models) | |
Type: | Standard SD (not SDHD or SDxC) |
Capacity: | 16MB to 2GB |
Real Time Clock (Stand-alone models) | |
Type: | Date, hour, minute, second |
Resolution: | 1 second |
Accuracy: | 20 ppm |
Transfer Rate to PC | |
Real Time: | up to 4,800 samples per second |
From Memory Card: | up to 3,000 samples per second |
General | |
Panel indicators: | Mode LED |
Panel Controls: | Control push button (Stand-alone models) |
Panel Slots: | Accepts MMC/SD-type flash memory |
Input connectors: | Two, removable sixteen position terminal blocks |
Operating Environment: | 0°C to 70°C |
Enclosure: | Aluminum base with steel wrap-around |
Dimensions: | 5.4375 "D × 4.125 "W × 1.5 "H (13.81D × 10.48W × 3.81H cm.) |
Weight: | 14 oz. |
Power Requirements: | USB: 9 to 36 VDC, 2 watts + 8B modules Ethernet: 9 to 36 VDC, 2.5 watts + 8B modules |
Indicators | |
Stand-alone models: | Three-color LED indicating Record, Standby, and Error conditions |
Standard models: | Power LED |
*Dependent on SD card used. Low speed SD cards can sample up to 2,000 Hz; High speed cards can sample up to 14,400 Hz. Some high speed cards cannot sample as high at 14,400 Hz but their capability can only be determined by trial and error (Model 101014-2G has been tested and approved).
Articles
Three Easy Steps for Stand-alone Data Logging
Stumbling Blocks to Stand-alone Data Logging
USB or Ethernet: Which Do I Choose?
Frequency and True RMS Data Acquisition
Intelligent Oversampling Methods Extend Measurement Flexibility
4-20mA Current Loop Data Acquisition
How To Choose Strain Gage-based Transducers for PC-based Data Acquisition Applications
Strain Gage-Based Transducer and Amplifier Selection and Calibration
How To Connect and Calibrate Thermocouples Using DI-8B47 Series Amplifiers
Connection and Calibration of Strain-Gage Based Transducers Using DI-8B38 Series Amplifiers
Powering Your Data Logger with a Battery
“Cannot allocate socket” Error when Attempting to Set a Static IP Address
Ethernet Installation to DHCP network
Ethernet Installation to Static IP network
Ethernet Installation Directly-connected (one DI-71x to one PC)
Values in WinDaq are not correct when using DI-8B42-01 Modules
Videos
Introducing the DI-718B
Measure analog voltage, temperature, process current, pressure, flow and more!
DI-71XS Configuration
Learn how to set up and configure channels on a DI-71X for stand-alone data logging.
DI-71X Internet Installation
Learn how to connect to your DI-71X Ethernet over the Internet through your router.
DI-71X-E Direct Connection
Learn how to connect and install a DI-71XE directly to your PC with a Static IP address.